go to main index know about us who we are and what we are provide ? we provide training on how to reach us send e-mail us
   

 

 

 

 

 

 

Motor failure with GSM modem

 

Introduction

In this project we will check failure of motor supply. If there will be any failure then our GSM modem will automatically generate sms. We have to save one mobile no. in microcontroller programming. When microcontroller will detect any pulse then our microcontroller will send message on saved mobile no. it is very interesting project, that’s why we selected this one.

 In this project we will use SIM300 GSM modem. AT commands will be there to send sms from GSM modem. 

VARIOUS STEPS OF PROJECT:

1)      POWER SUPPLY +5V

2)      MICROCONTROLLER AT89S52

3)      MAX232 CIRCUIT

4)      GSM MODEM

 

Pin no 40 is connected to the positive supply. In this project we provide a 5 volt dc power supply. This power supply is truly regulated power supply. Pin no 20 is connected to the negative supply. Here we supply a negative voltage on this pin. Crystal is connected to the pin no 18 and 19 of the microcontroller. Crystal provide a clock signal to run the vehicle and process all the internal requirement of the circuit.. For the regulated power supply we use ic 7805 as a regulator to provide a fix 5 volt power supply.

 

We will use GSM modem sm300 at 9600 baud rate.

GSM modem

This GSM modem is a highly flexible plug and play quad band GSM modem for direct and easy

integration to RS232. Supports features like Voice, Data/Fax, SMS,GPRS and integrated TCP/IP

stack.

Specifications for Fax

· Group 3, class 1

Specifications for data

· GPRS class 10: max 85.6 kbps(downlink)

· PBCCH support

· Coding schemes CS 1,2,3,4

· CSD upto 14.4 kbps

· USSD

· Non transparent mode

· PPP-Stack

 

Features

· Quad Band GSM/GPRS

850/900/1800/1900 Mhz

· GPRS multi-slot class 10/8

· GPRS Mobile station class B

· Compliant to GSM Phase 2/2+

o Class 4 (2W@850/900Mhz)

o Class 1(1W@1800/1900Mhz)

· Control via AT commands(GSM 07.07,

07.05 and enhanced AT commands)

· Operation Temperature(-20 deg C to

+55 deg C)

 

Specifications for SMS

· Point-to-point MO and MT

· SMS cell broadcast

· Text and PDU mode

Power Supply

· Use AC – DC Power Adaptor with following ratings

· DC Voltage : 12V

· DC Current : 1A

· Polarity : Centre +ve & Outside –ve

· Current Consumption in normal operation 250mA, can rise up to 1Amp while transmission.

Interfaces

· RS-232 through D-TYPE 9 pin connector, Serial port baud rate adjustable 1200 to115200

bps (9600 default)

· Stereo connector for MIC & SPK

· Power supply through DC socket

· SMA antenna connector

· Push switch type SIM holder

· LED status of GSM / GPRS module

Getting Started

· Insert SIM card: Press the yellow pin to remove the tray from the SIM cardholder. After

properly fixing the SIM card in the tray, insert the tray in the slot provided.

· Connect Antenna: Screw the RF antenna on the RF cable output provided.

· If voice call is needed, connect the mic and speaker to stereo sockets.

· Connect RS232 Cable: (Cable provided for RS232 communication) Default baud rate is

9600 with 8-N-1, no hardware handshaking. Cable provided has pins 7 and 8 shorted that will

set to no hardware handshaking. In you need hardware handshaking the pins 7-8 can be

taken for signaling.

o Pin 2 is RS232 level TX out

o Pin 3 is RS232 level RX in

o Pin 5 is Ground

o Pin 7 RTS in (shorted to pin 8 in cable for no hardware handshaking)

o Pin 8 CTS out (shorted to pin 7 in cable for no hardware handshaking)

Connect the power Supply (9-12V) to the power jack. Polarity should be Center +ve and

outer –ve DC jack.

Network Led indicating various status of GSM module eg. Power on, network registration &

GPRS connectivity.

After the Modem registers the network, led will blink in step of 3 seconds. At this stage you

can start using Modem for your application.

Examples for send and receive SMS

For sending SMS in text Mode:

AT+CMGF=1 press enter

AT+CMGS=”mobile number” press enter

Once The AT commands is given’ >’ prompt will be displayed on the screen.

Type the message to sent via SMS. After this, press ctrl+Z to send the SMS.

If the SMS sending is successful, “ok” will be displayed along with the message number.

For reading SMS in the text mode:

AT+CMGF=1 Press enter

AT+CMGR= no.

Number (no.) is the message index number stored in the sim card. For new SMS, URC will be received

on the screen as +CMTI: SM ‘no’. Use this number in the AT+CMGR number to read the message.

 

Component List

 

S.No.

Item

Quantity

Rate/Unit

1.       

MCU 89C051

1

80

2.       

GSM  MODEM

1

800

3.       

IR sensor 5 mm.

1

40

4.       

Thermocouple

1

40

5.       

3.38 MHz.

1

25

6.       

Buzzer

1

5

7.       

Condenser MIC

1

15

8.       

Speaker 8 ohm

1

30

9.       

Relay 12v 100 ohm

1

10

10.   

Transformer 6v 500mA

1

10

11.   

Power lead

1

20

12.   

Push to On Sw

4

1

13.   

 

SOLDERING WIRE

 

1

15

14.   

SOLDERING IRON

1

80

15.   

FLUX

1

45

16.   

CONNECTING WIRE

1

15

17.   

RESISTENCES

1

.5

18.   

CAPACITORS 1000µf

1

2

19.   

100uf,470uf

2

3

20.   

DIODES

2

2

21.   

LED

1

1

22.   

Crystal 12MHz

1

25

23.   

IC BASE

1

30

24.   

IC 7805 Volt. Reg

1

15

25.   

TRANSFORMER 9 V

1

30

26.   

RELAY 9V

1

15

27.   

MILER CAP

1

15

28.   

CRYSTAL 3.579545

1

20

29.   

HOLDER

1

10

30.   

PLY BOARD

1

150

31.   

TAPE ROLL

1

45

32.   

Copper Clad Board

1

150

 

 

 

 

 

Bibliography:

www.8051.com

www.atmel.com

www.8052.com

www.projectidea.com

Book – Ali mazidi