go to main index know about us who we are and what we are provide ? we provide training on how to reach us send e-mail us
   

 

Optical fiber losses Measurement

 

 

CONTENTS

S.N

TOPIC

PAGENO.

1.

INTRODUCTION TO BHARTI GROUP

2

2

THE GROUP STRUCTURE OF BHARTI

6

3

COMPANY SYNOPSIS

9

4

ABOUT THE LUDHIANA UNIT

11

5

THE PROFILE OF BHARTI SYSTEL LTD.

13

6

THE ORGANISATION CHART OF BSL

14

7

DIFFERENT TELEPHONE SETS

15

8

MAIN STORE

16

9

MOULDING SECTION

16

10

PRODUCTION ELECTRONICS     

22

11

PCB ASSEMBLY

25

12

WAVE SOLDERING

27

13

PCB TESTING

30

14

FINAL TESTING

31

15

FINAL REWORK

31

16

BASIC TELEPHONY

39

17

FINAL REWORK OF Bt2002

57

18

QUALITY CONTROL SYSTEM

69

19

CALLIBRATION ENSURES

88

20

RECEIPT AND ISSUING SECTION OF MATERIAL STORE

95

21

 

 

 

 

 

22

PROJECT REPORT

Optical fiber Communication

INTRODUACTION TO OPTICA FIBER.

OVERALL WORKING

BLOCK DIAGRAM

BIBILIOGRAPHY

97

 

98

112

130

168

     

 

 

 

 

 

 

INTRODUCTION:

 

 

 

In  this project we will measure optical bend losses using microcontroller 8051 and will display it on 16*2 LCD. We are making this project because wedidnot find any circuit on internet. In brief firstly we convert the LOSSES into small voltage variations with the help of sensor, Output of the sensor is further converted into digital signal with the help of the ADC. IN this project we use ADC0809 . ADC 0809 is a 8 bit ADC and convert the any analogue signal into digital signal in 100 microsecond. To control the ADC we required a clock pulse, and 4 different signal . All this signal is provided by the controller. IN this project we use ic 89s51 as a main controller. IC 89s51 sense the output from the ADC in hex code. This HEX code is further converted into binary code with the help of program code inside the controller. IN the output device we use LCD display . LCD display display the contents of the display with the  help of the ASCII code. ASCII CODE  is a special code for displaying the character in the LCD.  In the controller we convert the binary code in to ASCII codes with the help of the code conversion program.

 

 

 

 

 

COMPONENTS USED:

 

ADC           0809

OPAMP      OP07

TEMPERATURE SENSOR               LM 335

MICROCONTROLLER           89C51

LCD                                         2 BY 16

CRYSTAL                               3.58 MHz

 

 

RESISTOR

          10 K            11  Pc

          50 K            2 Pc   VARIABLE

          1 K              VARIABLE

          2.2K            1 Pc

          470 OHM    1Pc

         

 

CAPACITOR

          22 PF          2 Pc

          10 MFD       1 PC

 

PUSH TO ON SWITCH 2 PC.

 

7805 REGULATOR

STEP DOWN TRANSFORMER       9-0-9

DIODE        IN 4007( 4Pc)

 

Bibliography:

 

data-acquisition.globalspec.com/Industrial-Directory/adc_ic

 

ao.osa.org/abstract.cfm?uri=ao-45-31-8044

 